Home > Products > Microplate Reader

MTP-601Lab Fluorescence Microplate Reader

MTP-601Lab is specially developed for fluorescence ELIS A and fluorescent substrate measurement. It allows the detection and measurements of various cytokines, growth factors, intracellular-free calcium proteases and DNase.

Features and functions

Self-diagnosis function

Reminder for Halogen Lamp Replacement

When the usage exceeds the average life span of the lamp, the user will be prompted to replace the lamp.

Auto-Alignment Function

To Avoid variation and ensure consistency in measurements for different brands of microplates.

A versatile system that is capable of making minor adjustments according to the microplate manufacturer's parameters in order to obtain the most accurate resultes.

Plate Shaking Function

2. shaking mode: orbital or linear.

3. different speeds.

3. different durations: 5, 10 or 20 sec.

Specifications
Plate format 96 well plate (flat bottom,black)
Mode of Detection Fluorescence
Mode of Measurement End point/Kinetic measurement
Sensitivity Fluorecein: 2×10-11mol/L
Bandpass filter Excitation:490 nm
Emission:530 nm
Wavelength Range Excitation:360 ~ 710 nm
Emission:400 ~ 750 nm
Mixing Mode Orbital/linear; 3 speeds; 3 durations
Measurement Interval & Frequencyy 999 seconds or less; 99 times
Measurement duration min 60 s /96 well plate
Light Source Halogen lamp
Detector Photomultiplier Tube

    SH-8000Lab Grating Microplate Reader

  • SH-8000Lab pursues flexibility, high reliability, and innovation to respond to a
    wide range of measurement needs.
  • Measurement mode: fluorescent/ Time resolved fluoroisnmunoassay/ absorbance/ (fluorescence polarization OP)/ (luminescence OP)
  • Better accuracy for the measurement, since two wavelength ratio has done for two excitation and two emission measurement.
  • Wavelength range
    F luorescence : 200 ~ 900 nm
    Time-resolved Fluorescence : 350 ~ 650 nm
    F luorescence Polarization (option) : 350 ~ 750 nm
    Absorbance : 200 ~ 1000 nm
    Luminescence (option) : 350 ~ 650 nm
  • Fluorescence sensitivity : fluorescein 510-11mol/L (96 well ELISA plate)
  • Time resolved fluoroisnmunoassay sensitivity : europium 510-12mol/L (filter method)
  • Luminescence measurement : 2.5 x 10-19mol ALP
  • Absorbance measurement : -0.5 ~ 3.5Abs/ 0.5%T or 0.005Abs (0 ~ 2.5Abs 492nm)
  • Absorbance Repeatability : CV 1.0% or less (OD 1.0)

    SH-8000Lab Grating Microplate Reader

  • SH-8000Lab pursues flexibility, high reliability, and innovation to respond to a
    wide range of measurement needs.
  • Measurement mode: fluorescent/ Time resolved fluoroisnmunoassay/ absorbance/ (fluorescence polarization OP)/ (luminescence OP)
  • Better accuracy for the measurement, since two wavelength ratio has done for two excitation and two emission measurement.
  • Wavelength range
    F luorescence : 200 ~ 900 nm
    Time-resolved Fluorescence : 350 ~ 650 nm
    F luorescence Polarization (option) : 350 ~ 750 nm
    Absorbance : 200 ~ 1000 nm
    Luminescence (option) : 350 ~ 650 nm
  • Fluorescence sensitivity : fluorescein 5×10-11mol/L (96 well ELISA plate)
  • Time resolved fluoroisnmunoassay sensitivity : europium 5×10-12mol/L (filter method)
  • Luminescence measurement : 2.5 x 10-19mol ALP
  • Absorbance measurement : -0.5 ~ 3.5Abs/ ±0.5%T or ±0.005Abs (0 ~ 2.5Abs 492nm)
  • Absorbance Repeatability : CV 1.0% or less (OD 1.0)